               |
Fast Check !
Metrel Alphatek BetaPAT |
| Earth Bond |
 |
| Insulation |
 |
| Load/Run |
 |
| Leakage |
 |
| Touch Current |
 |
| Substitute Leakage |
 |
| Polarity |
 |
| Memory |
 |
| Qwerty Keyboard |
 |
| Download |
 |
| IT Safe |
 |
| Dual Voltage |
 |
| Flash |
|
PAT Training Services Limited
Glendales House
607 York Road
LEEDS
LS9 6NW UK
Tel: 0113 2489966
Fax: 0113 2484276
email admin@pat-training.co.uk
PAT Training Services Limited
Glendales House
607 York Road
LEEDS
LS9 6NW UK
Tel: 0113 2489966
Fax: 0113 2484276
email admin@pat-training.co.uk |
 |
|
 |
Metrel / Alphatek BETAPAT MI2141
PAT Tester Equipment
|

SAVE £134.00
only £765 + VAT
We also give you a FREE roll of PAT Testing PASS & FAIL Labels worth £29 pounds when you order a BetaPAT from us!
BetaPAT Datasheet
|
Alphatek's BetaPAT PAT Tester is packed with time saving features. The Metrel Beta PAT can test Class 1, Class II and Class III electrical appliances. The Metrel BetaPAT is a downloadable PAT Tester equipped with a QWERTY keyboard for PAT testing data input. Results can be stored on the Beta PAT and then downloaded onto the optional SimplyPATs Version 5 Software
The Metrel BetaPAT PAT Tester is a Dual Voltage PAT Tester with an inbuilt 110V transformer meaning that the Metrel BetaPAT can run on, and test both 110V and 230V appliances.
The PAT Tester is enclosed in a strong polycarbonate case, making it an ideal solution for testing on Building Sites, Factories, and other industrial areas.
It can store electrical appliance names e.g. PC, VDU, Kettle, angle grinder, photocopier etc., plus Building/Customer names and Room/Department names for default recall.
A unique timesaving function.
The unit differs from the Alphatek OmegaPAT as this unit does not have a flash test facility, The IEE guidance notes do not recommend a flash test for in-service testing of electrical equipment as this can damage equipment.
Measurements and testing
in accordance with:
IEC 60335-1 - Household and similar electrical appliance
IEC 60598-1 - Luminaries
IEC 60745 - Hand-held motor operated tools
IEC 60950 - Safety of information technology equipment
VDE 701 T1 - Repair and modification inspections
VDE 702 T1 - Repair tests of electrical appliances
|
| Alphatek BetaPAT Portable Appliance Tester / Metrel BetaPAT |
|
Rugged designed case stores all leads
Stores up to 8000 test results, can download these
in 6 min's
Qwerty keyboard for fast input of appliance details
Will run and operate on both 110V and 230V supply
Large display
with graphic and test help screens
Automatic or user defined pass / fail limits and
test parameters
Stores fail reasons for downloading to a PC
230V IEC lead tester
Accurate earth bond and leakage measurement even
when multiple earth
paths exist |
|
| What
we include in the price:
Order Code: BetaPAT / Metrel BetaPAT |
| 1. |
Alphatek Mtrel BetaPAT
PAT Tester. |
| 2. |
Manufacturers Certificate of Calibration |
| 3. |
Removable
earth bond lead |
| 4. |
Internal
storage pouch |
| 5. |
Instruction
manual |
| 6. |
36
months manufacturers warranty |
|
| Alpha Tech BetaPAT Tester variations: |
| BetaPAT MI2141 |
Beta PAT as above with FREE Labels: 500 Pass Labels + 200 Fail Labels |
|
| BetaPAT MI2141 SP |
Beta PAT as above with Pat Link Software, RS232 Cable and FREE Labels: 2000 Pass Labels + 200 Fail Labels |
|
| BetaPAT MI2141 CP |
Beta PAT with Pat Link Software, RS232 Cable & bar code scanner, 1000 Bar code Appliance ID Labels, and FREE Labels: 2000 Pass Labels and 200 Fail Labels |
|
| BetaPAT MI2141 CP 07 Kit |
Beta PAT with SimplyPATS Version 4 Software (Compatable up to Windows XP)Package, RS232 Cable & bar code scanner, 1000 Bar code Appliance ID Labels, and FREE Labels: 2000 Pass Labels and 200 Fail Labels |
|
| BetaPAT MI2141 CP 08 Kit |
Beta PAT with SimplyPATS Version 5 Software (Compatable with windows VISTA) Package, RS232 Cable & bar code scanner, 1000 Bar code Appliance ID Labels, and FREE Labels: 2000 Pass Labels and 200 Fail Labels |
|
There is also another version called the Metrel OmegaPAT with a flash test facility: Click  |
| Specifications: Metrel Alphatek Beta PAT tester |
| Earth
Bond Continuity: |
Test
currents of 100mA DC, 4amps, 10amps or 25
amps AC
Measuring Range 0.00 - 19.9 ohms |
| Insulation
Test: |
Carried out at either 250V or 500V DC, Range
0.000 - 199.9 Mohms |
| Substitute
Leakage: |
Test voltage 40V Measuring range: 0.00- 1.99
mA |
| Touch
Leakage: |
Measuring range: 0.00- 19.99 mA |
|
Differential Leakage: |
Measuring range: 0.00- 19.99 mA |
| Power: |
Measuring range: 0 - 4 kVA |
| Polarity |
Faults:
open, short, crossed, multiple fault |
| Weight
& Dimensions |
9
kg, 335 x 160 x 335mm |
| Popular accessories for the Alphatek BetaPAT PAT Tester: (click images) |
|
|
|
|
|
|
|
110 Volt Extension Lead Test Adapter |
SimplyPATs Software Version 5
|
PAT Tester Tool Kit inc's fuses, labels, screwdriver, permanent pen, voltage detector |
|
|
|
|
|
£19 |
|
|
|
|
200Fail £10
500Pass£19
1000BC £39 |
£ 295 |
Prices excludes delivery carriage @ £10
and VAT @ 15%
|
|
|
Copyright © 2004 - 2009
PAT Training Services Limited, All rights reserved. E&OE
|
|
|